Chapter 5 Section I: Replacement Procedures
10/100Base-T LEDs and Dipswitches
The 10/100Base-T PrintNet Ethernet interface has two indicator lights, as
shown below.
Run and Auto Reset Modes
Run Mode is the normal operating state of this interface. Auto Reset mode is
entered when the watchdog timer is triggered and the print server resets itself.
In either mode, the STAT LED flashes at a varying rate, depending on
whether the unit IP address is configured. The Run Mode and Auto Reset
Mode indicator descriptions are shown in Table 9.
Table 9. Run Mode and Auto Reset Mode Indicator Descriptions
STAT Rate Indication
Flashes On once per second Normal Mode, IP address
configured
Flashes On 2 times per
second
IP address not configured
Flashes Off once per second Download (MOS)
Flashes Off twice per second Error
On constantly Indicates link integrity
Flashes Off 1/3 second Flashes off 1/3 second each time a
packet is transmitted